Below are all the different types of Omnitron Systems Technology. Select the device of your choice, to download the manual


Click here to download the manual

Contents

NOTE The iConverter CWDM X modules can not be installed in slots 4 8 12 and 16 of a 19 Module Chassis or in the top slot of a 2 Module Chassis or in a 1 Module Redundant Power Chassis NOTE The iConverter 8 Channel Double Wide CWDM X can only be installed in a 2 Module Chassis or 19 Module Chassis with the exception of slots 4 5 8 9 12 13 and 16 17 Design Considerations iConverter CWDM X modules are passive devices that require no external power Attenuation signal loss of less than 2 7dB will be realized through each port on the module see the CWDM X Data Sheet for exact loss specification for each model Detailed calculations should be performed for each fiber optic link in the network to ensure the proper optical devices are specified with sufficient tran ...